Description
NEW and NEVER USED!
Lot 11 – JOHNSTON BOILER COMPANY PACKAGED FIRETUBE STEAM BOILER (BOILER # 1) Model / Cat. No. PFTS2335-3LG200S Unit No. / S/N 10720-01 (Mfg. 2008), 2335 hp, 3- Pass, 200 psig Designed Pressure, having Johnston Series "S" Burner, Natural Gas Fired, Max Gas Firing Rate 99.500 BTU, Type of Oil #2, Max Oil Firing Rate 685 gal. Consisting of but not necessarily limited to: Boiler Section: Base Frame having MAXON, FISHER and other Control and Safety Valves and Miscellaneous Boiler Trim, with QUINCY Model 5120L 106 Air Compressor, S/N 20080426-0103 powered by RELIANCE 25 hp Electric Motor.
With NEW YORK BLOWER AF-THIRTY FAN, BOILER #1, FORCED DRAFT FAN, (ASSUMED) 44AF Wheel Size and Type C09791-100 (Mfg. 2008), 25,600 cfm, 70° F powered by BALDOR 150 hp Electric Motor S/N S9005663-001 002 DL; 3- Pieces Exhaust Stack Transition, 1- Piece having a Damper.
With ELECTRICAL CONTROL PANEL, Having but not necessarily limited to: FIREYE® Nexus Integrated Burner, HMI Controls, 3- Digital Read-outs, 12- Circuit Control Switches and Indicator Lighting; FIREYE® 2- Flame Monitor Modules; PPC 5000 Module, Model 129-145-1, Type ED510 Display Module and ED580 Cable to EP Programmer.
With LOT MISCELLANEOUS COMPONENTS, 5- Pallets consisting of but not necessarily limited to: Components, Parts, and Supplies for the Boilers, the Blow Down Unit and Economizer.
Lot 12 – JOHNSTON BOILER COMPANY PACKAGED FIRETUBE STEAM BOILER (BOILER # 2) Cat. No. PFTS2335-3LG200S Unit No. / S/N 10720-02 (Mfg. 2008), 2335 hp, 3- Pass, 200 psig Designed Pressure, having Johnston Series "S" Burner, Natural Gas Fired, Max Gas Firing Rate 99.500 BTU, Type of Oil #2, Max Oil Firing Rate 685 gal. Consisting of but not necessarily limited to: Boiler Section: Base Frame having MAXON, FISHER and other Control and Safety Valves and Miscellaneous Boiler Trim, with QUINCY Model 5120L 106 Air Compressor, S/N 20080418-0103 powered by RELIANCE 25 hp Electric Motor.
With NEW YORK BLOWER AF-THIRTY FAN, BOILER #2, FORCED DRAFT FAN, (ASSUMED) 44AF Wheel Size and Type C09791-100 (Mfg. 2008), 25,600 cfm, 70° F powered by BALDOR 150 hp Electric Motor S/N S9005663-001 004 DL; 3- Pieces Exhaust Stack Transition, 1- Piece having a Damper.
With ELECTRICAL CONTROL PANEL, Having but not necessarily limited to: FIREYE® Nexus Integrated Burner, HMI Controls, 3- Digital Read-outs, 12- Circuit Control Switches and Indicator Lighting; FIREYE® 2- Flame Monitor Modules; PPC 5000 Module, Model 129-145-1, Type ED510 Display Module and ED580 Cable to EP Programmer.
With LOT MISCELLANEOUS COMPONENTS, 3- Pallets consisting of but not necessarily limited to: Components, Parts, and Supplies for the Boilers, the Blow Down Unit and Economizer.
Contact us to MAKE AN OFFER!
Lot 11 – JOHNSTON BOILER COMPANY PACKAGED FIRETUBE STEAM BOILER (BOILER # 1) Model / Cat. No. PFTS2335-3LG200S Unit No. / S/N 10720-01 (Mfg. 2008), 2335 hp, 3- Pass, 200 psig Designed Pressure, having Johnston Series "S" Burner, Natural Gas Fired, Max Gas Firing Rate 99.500 BTU, Type of Oil #2, Max Oil Firing Rate 685 gal. Consisting of but not necessarily limited to: Boiler Section: Base Frame having MAXON, FISHER and other Control and Safety Valves and Miscellaneous Boiler Trim, with QUINCY Model 5120L 106 Air Compressor, S/N 20080426-0103 powered by RELIANCE 25 hp Electric Motor.
With NEW YORK BLOWER AF-THIRTY FAN, BOILER #1, FORCED DRAFT FAN, (ASSUMED) 44AF Wheel Size and Type C09791-100 (Mfg. 2008), 25,600 cfm, 70° F powered by BALDOR 150 hp Electric Motor S/N S9005663-001 002 DL; 3- Pieces Exhaust Stack Transition, 1- Piece having a Damper.
With ELECTRICAL CONTROL PANEL, Having but not necessarily limited to: FIREYE® Nexus Integrated Burner, HMI Controls, 3- Digital Read-outs, 12- Circuit Control Switches and Indicator Lighting; FIREYE® 2- Flame Monitor Modules; PPC 5000 Module, Model 129-145-1, Type ED510 Display Module and ED580 Cable to EP Programmer.
With LOT MISCELLANEOUS COMPONENTS, 5- Pallets consisting of but not necessarily limited to: Components, Parts, and Supplies for the Boilers, the Blow Down Unit and Economizer.
Lot 12 – JOHNSTON BOILER COMPANY PACKAGED FIRETUBE STEAM BOILER (BOILER # 2) Cat. No. PFTS2335-3LG200S Unit No. / S/N 10720-02 (Mfg. 2008), 2335 hp, 3- Pass, 200 psig Designed Pressure, having Johnston Series "S" Burner, Natural Gas Fired, Max Gas Firing Rate 99.500 BTU, Type of Oil #2, Max Oil Firing Rate 685 gal. Consisting of but not necessarily limited to: Boiler Section: Base Frame having MAXON, FISHER and other Control and Safety Valves and Miscellaneous Boiler Trim, with QUINCY Model 5120L 106 Air Compressor, S/N 20080418-0103 powered by RELIANCE 25 hp Electric Motor.
With NEW YORK BLOWER AF-THIRTY FAN, BOILER #2, FORCED DRAFT FAN, (ASSUMED) 44AF Wheel Size and Type C09791-100 (Mfg. 2008), 25,600 cfm, 70° F powered by BALDOR 150 hp Electric Motor S/N S9005663-001 004 DL; 3- Pieces Exhaust Stack Transition, 1- Piece having a Damper.
With ELECTRICAL CONTROL PANEL, Having but not necessarily limited to: FIREYE® Nexus Integrated Burner, HMI Controls, 3- Digital Read-outs, 12- Circuit Control Switches and Indicator Lighting; FIREYE® 2- Flame Monitor Modules; PPC 5000 Module, Model 129-145-1, Type ED510 Display Module and ED580 Cable to EP Programmer.
With LOT MISCELLANEOUS COMPONENTS, 3- Pallets consisting of but not necessarily limited to: Components, Parts, and Supplies for the Boilers, the Blow Down Unit and Economizer.
Contact us to MAKE AN OFFER!
Payment Information
10% Buyer’s Premium. No equipment can be removed from the site without full payment. Sales tax may apply.
Full Terms
Selling AS-IS, WHERE-IS WITH NO WARRANTIES, GUARANTEES, EXPRESS OR IMPLIED. Items left longer than 30 days are subject to forfeiture. Removal, packaging and transportation costs are the responsibility of buyer. All sales are final.
In all transactions, Maas Companies is acting as an Agent for the Seller. Buyers are urged to inspect items prior to purchase. Seller and Auctioneer are not responsible for items. All information received from reliable sources believed to be correct but not guaranteed by the Auction Company.